Do Split System Air Conditioners Need Regassing? Signs of a Refrigerant Leak

On this page
- Do Split Systems Need Regassing?
- Does Refrigerant Run Out?
- How Often Should a Split System Be Regassed?
- Why Is My Split System Low on Refrigerant?
- What Are the Signs of a Refrigerant Leak?
- Can Low Refrigerant Cause Ice?
- Can Low Refrigerant Cause Poor Heating?
- Can You Simply Top Up the Gas?
- Does the Leak Need to Be Repaired First?
- How Much Does Regassing Cost?
- Can Homeowners Add Refrigerant Themselves?
- Get Your Split System Checked Properly
Many homeowners believe a split system needs regassing every few years, in the same way a car needs an oil change. In reality, refrigerant does not get used up, and a correctly installed system should never need a top-up. If you are researching Split Air Conditioning Perth because your system is not cooling or heating as well as it used to, low refrigerant may be the cause, but a regas on its own is rarely the answer. This guide explains how refrigerant works, the signs of a leak and when regassing is actually appropriate.
Do Split Systems Need Regassing?
No, not as a routine part of ownership. A split system is a sealed system. The refrigerant circulates between the indoor and outdoor units, changing from liquid to gas and back again, but it is not consumed in the process.
A split system only needs regassing when:
- There is a leak, which has been found and repaired
- A major component has been replaced, such as a compressor or coil, and the refrigerant had to be recovered
- The system has been relocated or reinstalled, and the refrigerant was recovered before the move
- The original installation was undercharged, which a technician can identify when checking pressures
If someone recommends regassing your split system as regular maintenance, ask why. A properly working system should hold the same charge for its whole life.
Does Refrigerant Run Out?
No. Refrigerant is not a fuel. It works more like the blood in a circulatory system, carrying heat from one place to another and returning to be used again.
This is one of the most common misconceptions about air conditioning. Unlike petrol in a car, refrigerant does not burn off or wear out. If the level is low, it has escaped through a leak somewhere in the system.
How Often Should a Split System Be Regassed?
Ideally, never. A well-installed system with no leaks should hold its refrigerant charge for its entire working life.
If your system has needed regassing more than once, it almost certainly has a leak that has not been properly repaired. Each top-up only buys time until the refrigerant escapes again, and the cost of repeated regassing quickly adds up.
Rather than scheduling regular regassing, book an annual service. During a service, a technician checks the refrigerant pressures and looks for signs of a leak, so problems can be caught early.
Why Is My Split System Low on Refrigerant?
If your split system is low on refrigerant, there is a leak. Common causes include:
- Poorly made flare joints where the pipework connects to the indoor and outdoor units, which is one of the most common sources of leaks
- Vibration over time, which can loosen joints or wear pipework where it rubs against brackets or walls
- Corrosion of the coils, particularly in coastal suburbs where salty air attacks the outdoor unit
- Physical damage, such as pipework knocked during renovations, gardening or building work
- Manufacturing defects in coils or components, which are less common but do occur
- Installation faults, such as kinked pipes or poorly sealed connections
Some leaks are slow and may take months or years to cause a noticeable drop in performance. Others are fast and can empty the system within days.
What Are the Signs of a Refrigerant Leak?
Signs that your split system may be leaking refrigerant include:
- Reduced cooling or heating, with the air coming out lukewarm rather than cold or warm
- The system running for longer to reach the set temperature
- Ice or frost on the indoor coil, the pipework or the outdoor unit
- A hissing or bubbling sound near the pipes or the indoor unit
- Oily residue around pipe joints, as refrigerant oil often escapes with the gas
- Higher electricity bills because the system is working harder
- Water dripping from the indoor unit, caused by ice on the coil melting
Many of these signs can also be caused by dirty filters or a failing fan, so a technician needs to test the system to confirm a leak.
Can Low Refrigerant Cause Ice?
Yes. When a split system is low on refrigerant, the pressure inside the indoor coil drops, which causes the coil to run colder than it should. Moisture in the air then freezes onto the coil or the pipework.
Ice can also form because of dirty filters or a faulty fan, which reduce airflow across the coil. Whatever the cause, ice on the indoor coil or pipes is a sign that the system needs attention.
If you notice ice, switch the system off and let it thaw, then book a technician. Running the system with ice on the coil can damage the compressor.
Can Low Refrigerant Cause Poor Heating?
Yes. A reverse cycle split system uses the same refrigerant to heat as it does to cool. In heating mode, the refrigerant absorbs heat from the outside air and releases it inside your home. If the system is low on refrigerant, it cannot move as much heat, so the air coming out feels lukewarm.
Low refrigerant can also cause the outdoor unit to ice up more than usual in winter, leading to longer and more frequent defrost cycles.
If your system struggles to both heat in winter and cool in summer, a refrigerant leak is a likely cause.
Can You Simply Top Up the Gas?
No. Simply topping up the gas without finding and fixing the leak is a short-term fix that wastes money, harms the environment and is not allowed under Australian refrigerant handling rules.
According to the Australian Refrigeration Council, topping up a system before it has been fully tested and all identified leaks repaired is illegal.
Topping up without a repair also causes practical problems:
- The refrigerant will leak out again, so you will need to pay for another regas
- Escaping refrigerant contributes to greenhouse gas emissions
- Running a system with fluctuating refrigerant levels puts extra strain on the compressor, which is the most expensive part to replace
Be cautious of any business offering a cheap gas top-up without testing the system for leaks.
Does the Leak Need to Be Repaired First?
Yes. A proper refrigerant repair follows a clear process:
- Find the leak. The technician uses electronic leak detection, bubble testing or nitrogen pressure testing to locate the leak.
- Recover the remaining refrigerant. Any refrigerant left in the system is safely recovered using specialised equipment.
- Repair the leak. This may involve remaking a flare joint, brazing pipework or replacing a damaged coil.
- Pressure test the system. The system is pressurised with nitrogen to confirm the repair holds.
- Evacuate the system. A vacuum pump removes air and moisture from the pipework.
- Recharge with the correct refrigerant. The system is charged with the right type and amount of refrigerant.
- Test performance. The technician checks pressures, temperatures and operation.
Some leaks are simple to fix, such as a loose flare joint. Others, such as a leak inside a corroded coil, may mean a major component needs replacing. On an older system, this can be the point where replacing the whole unit becomes the better value option.
How Much Does Regassing Cost?
As a general guide based on Australian market estimates:
- Regassing a small split system (up to around 5 kW) typically costs around $200 to $300
- Regassing a larger split system (6 kW and above) typically costs around $250 to $400
- Leak detection may add around $80 to $150, depending on how hard the leak is to find
- Leak repairs are charged on top, depending on the location and type of repair
The type of refrigerant also affects the price. Most modern split systems use R32 or R410A. Older systems that use R22 can cost two to three times as much to regas, as R22 has been phased out in Australia and is now scarce and expensive. If your system uses R22 and has a leak, replacing it is often the better long-term option.
These figures are estimates only. Your technician will provide a quote after inspecting the system.
Can Homeowners Add Refrigerant Themselves?
No. In Australia, handling refrigerant requires a refrigerant handling licence issued by the Australian Refrigeration Council. This applies to regassing, recovering refrigerant and repairing leaks.
There are good reasons for these rules:
- Safety: Refrigerant is stored under high pressure and can cause frostbite and other injuries. Some modern refrigerants, such as R32, are mildly flammable.
- Environmental protection: Refrigerants are powerful greenhouse gases, and releasing them into the atmosphere is prohibited.
- Correct charging: Adding the wrong amount or type of refrigerant can damage the system and reduce efficiency.
- Warranty: Unlicensed work can void the manufacturer’s warranty.
Even some licensed installers are limited in what they can do. A restricted split system licence covers installation but does not cover service or repair work that involves handling refrigerant. For leak repairs and regassing, make sure your technician holds a full refrigeration and air conditioning licence.
Get Your Split System Checked Properly
If your split system is not cooling or heating as well as it should, do not assume it simply needs more gas. A proper inspection will confirm whether there is a leak, find the cause and fix it before the system is recharged.
Refrigwest’s fully licensed technicians repair and service split system air conditioners across Perth, from Two Rocks to Mandurah and out to the Perth Hills. Every service includes refrigerant pressure checks and leak testing, and every repair is quoted before work starts.
Call 1300 164 217 to book a split system inspection or repair.